ECS supports the efforts of Live Earth and the SOS campaign. Click here to get more energy saving tips. every little bit helps.
Intellidyne Guarantee
ECS and Intellidyne are so confident that the IntelliCon products offered will reduce your energy consumption by a minimum of 10% in the first year, or we will refund your entire purchase price if we are unable to attain these savings. Ask you sales rep for details.
|
IntelliCon®-CHS is a microprocessor-controlled fuel-saving
device for commercial steam heating systems. IntelliCon-CHS reduces: fuel consumption, wear on parts, fuel
emissions, and electrical usage, when installed on any new or existing gas or
oil burner. IntelliCon-CHS saves energy by adjusting the burner run pattern to match the
system's "heat load." Its action is similar to the industry-accepted method of
"outdoor-air temperature reset control," but does not require an outdoor-air
temperature sensor or the need to profile the building in order to adjust the
"reset" controller properly. IntelliCon-CHS determines the "heat load" by using an easily
installed pressure sensor that monitors the boiler's steam-pressure and the
rate that this pressure is changing.
Any heating system must
be able to provide acceptable comfort at the lowest anticipated outdoor
temperature. In the U.S. and abroad, most light commercial boilers have a heat
capacity between 1.5 to 2 times larger than that needed to maintain the facility's
temperature on those extreme days. Due to this over-sizing of the boiler, the
burner will cycle on and off continuously to maintain the desired steam
pressure.
Using our patented technology, IntelliCon®-CHS increases "system efficiency" thus
the heating system uses less fuel to generate the same amount of heat. This is
done by dynamically changing the pressure-controller's effective dead-band
based upon the measured "heating load." This causes the average steam pressure
to be varied (depending upon the measured load), and is accomplished by
extending the burner's "off-time." Extending the "off-time" also results in
longer burns that are more efficient and a reduction in burner on/off cycling.
Just as computer control has increased the gas mileage of automobiles: IntelliCon-CHS
improves the fuel utilization of heating systems, by supplementing the
antiquated on/off control action of the pressure-controller with the analysis
and control capabilities of a computer.
Service personnel will appreciate
the LCD readout, which displays useful information relative to the unit's
status, steam pressure and domestic hot-water temperature (if the optional
sensor is installed), which can be useful for system diagnostics and maintenance.
IntelliCon-CHS
typically reduces fuel consumption 10% to 20% and decreases burner cycling 30%
or more. The unit does not require any programming or adjustments and after
installation, IntelliCon-CHS
requires no maintenance.
FEATURES
- Patented process reduces fuel
consumption -typically 10% to 20%
-
Short payback period -
typically 4 to 18 months
-
UL listed (pending),
"Energy Management Equipment"
-
Increased savings
without replacing or upgrading costly system components
-
"State-of-the-art"
microcomputer controller
-
Easily installed plug-in
sensor's)
-
Illuminated LCD display
shows operating modes, diagnostics, system temperatures
-
Fail-safe operation
-
No programming or
follow-up visits required
- Maximum
efficiency year-round
-
Reduces
maintenance and extends boiler life
-
Guaranteed
to reduce fuel consumption
-
15-year
replacement warranty for breakdowns or defects
|
Customer News
|
NYSERDA President On IntelliCon |
|
Peter R. Smith, NYSERDA President and CEO, said, “From a fuel oil efficiency and air emissions perspective, these results are very encouraging. The results of this study of the IntelliCon control system can benefit customers, our environment.
|
|
Read more...
|
|
|